Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

4T-6

Part # 4T-6
Description 6 DB, DC-18.0 GHZ, 2 W
Category COAX CONNECTOR
Availability In Stock
Qty 1
Qty Price
1 + $145.99917
Manufacturer Available Qty
WIENSCHEL ENGINEERING
  • Shipping Freelance Stock: 1
    Ships Immediately



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

XW2Z
XW2Z
3
Dimensions
Unit: mm (inch)
3
XW2Z-
PPP
A FOR 32-POINT PLC I/O MODULES (CONNECTOR TYPE)
The G79-
P
C Cable with a connector for the G7TC cannot be
used for the XW2C due to a difference in wiring. The G79-
P
C
Cable can be used for some of the XW2B Screw Terminal
Blocks, refer to the XW2B data sheet.
Cable length L
Part number Cable length L
XW2Z-050A 0.5 m (1.64 ft)
XW2Z-100A 1 m (3.28 ft)
XW2Z-150A 1.5 m (4.92 ft)
XW2Z-200A 2 m (6.56 ft)
XW2Z-300A 3 m (9.84 ft)
XW2Z-500A 5 m (16.40 ft)
Wiring Diagram
FCN-367J024-AU/F
(mated side)
XG4M-2030
(mated side)
Triangle mark
Combinations of Omron PLC I/O Modules and Screw Terminal Blocks
PLC I/O module I/O points Terminal block Dedicated cable
C200H-ID215
C200H-OD215
C200H-MD215
C200H-MD115
C200H-MD501
C200H-ID501
C200H-OD501
C500-ID218CN
C500-ID501CN
C500-OD415CN
C500-MD211CN
C500-OD501CN
32 points input
32 points output
16 points in/16 points out
16 points in/16 points out
16 points in/16 points out
32 points input
32 points output
32 points input
32 points input
32 points output
16 points in/16 points out
32 points output
XW2B-20G5
XW2B-20G4
XW2B-40G5-T
XW2B-20G5-D
XW2Z-
PPP
A
C200H-ID215
C200H-ID501
C500-ID218CN
C500-ID501CN
C200H-MD215
C200H-MD115
C200H-MD501
C500--MD211CN
32 points input
32 points input
32 points input
32 points input
16 points in/16 points out
16 points in/16 points out
16 points in/16 points out
16 points in/16 points out
XW2C-20G5-IN16
(See Note 3)
Note: 1. The G79-
P
Cable with a connector for the G7TC cannot be used for the XW2C due to a difference in wiring. The G79-
P
C
Cable can be used for some of the XW2B Screw Terminal Blocks, refer to the XW2B data sheet.
2. The Input or Output Modules above have two connectors, so each one can use up to two Terminal Blocks and two dedicated
cables.
3. The XW2C is a dedicated Input Terminal Block. If the XW2C is connected to a PLC module that handles both input and output
signals (modules with “MD” in the part number), only the input portion of the PLC module can be used.
12345NEXT