Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

143200

Part # 143200
Description TYPE III 58VDC 200 AMPMANUAL RESET PANEL MOUNT
Category CIRCUIT BREAKER
Availability Available With Additional Lead Time
Qty 0
Qty Price
1 - 99 $29.02900
100 - 999 $21.72262
1,000 - 4,999 $19.93622
5,000 - 9,999 $18.52497
10,000 + $12.24960
Manufacturer Available Qty
Optifuse
  • Additional Qty
      Lead Time:
    12 weeks



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

124
SAK-series
SAK-series
SAK-series
125
Weidmüller terminal - SAK-series- are pro-
ved in millions of applications for more
than 50 years.
Available for the two rail systems TS32
and TS35, the SAK terminals are useable
for every application and for all cross-sec-
tions. SAK terminals fulfill the requirements
of EN 60 947-7-1.
Thermosetting plastic or
Thermoplastic
Terminal of thermosetting plastic are nor-
mally used in applications where high con-
tinuous service temperature and high
flammability level are necessary. The
Weidmüller thermosetting plastic KRG is
very resistant against infection through
mould and micro-organisms.
The thermoplastic material Polyamide 66
has very good electrical and mechanical
properties upto 100°C. PA66 is flexible
and unsusceptible to fracture, even with
low temperatures.
Polyamid 66 has improved fire resistance
and is self-extinguishing with flammability
level V2 according to UL 94.
Cross-connection systems
40% of all terminals are cross-connected
for potential branching.
Weidmüller distinguishes between the fol-
lowing cross-connection units for SAK-
series:
type Q pre-assembled cross-connec-
tions
type QL permanent cross-connections
type VL removeable cross-connection
straps
type QS removeable cross-connection
plugs
Cross-connection systems from the SAK
and AKZ series, type Q, QL or VL or other
freely accessible live components, must be
protected with appropriate covers ADP 1
or 4 or TSK 31.5 as long as they are to be
inserted safe from contact.
Approvals
The following approvals apply to SAK ter-
minals:
a UL-USA
r CSA-Canada
# GOST-Russia
q SEV-Switzerland
i
KEMA-Netherlands
LR Lloyds Register of Shipping
u
Germanischer Lloyd
DNV
Det Norske Veritas
SAK portfolio
Feed-through terminals
•Protective conductor terminals
Fuse terminals
•Disconnect-test terminals
Feed-through terminals with tab, solder,
WireWrap and Termi Point connections
Initiator terminals, Actuator terminals
Stud terminals
Accessories
An extensive assortment of accessories is
available for Weidmüller SAK terminals:
Partitions
Cover plates
Small partitions
•Test plugs
•Test adapters
Marking material
•Cross-connections and
Covers
TS 32
Thermosetting
plastic
Thermoplastic
TS 35
Positioning of end plates or partitions between cross-connections
Operating voltage Terminal width (in mm)
3 6 3 810 121822
125 V ~ AP –––––
250 V ~ AP –––––
380 V ~ AP AP ––––
440 V ~ TW AP AP AP AP
500 V ~ TW TW AP AP AP
660 V ~ TW TW TW TW TW AP
750 V ~ TW TW TW TW TW AP
In PA terminals small partitions (TSch) have to be used up to 380 V.
126
Feed-through terminals
Mounting rails, end brackets, further marking material see “Accessories”
1
) Contact-proof with ADP 4 cover profile (see section “Accessories”)
3
) Cat. No. 0279660000, 0279680000, 0380460000
2
) Not suitable for SST 3 safety pin and 0380480000, 41 A for 6 mm
2
W
W
W
Y
Y
Dimensions/approvals
Width/length/height (mm) with TS 32 Y
Width/length/height (mm) with TS 35 x 7.5 W
Insulation stripping length/clamping screw/screwdriver blade
Rated data according to IEC 60 947-7-1
Rated voltage/current/cross-section
Rated impulse voltage/pollution severity
Further technical data
Tightening torque range Nm
Torque setting with electric screwdriver type DMS 2
Clampable conductor
Solid H07V-U mm
2
Stranded H07V-R mm
2
Flexible H07V-K mm
2
Flexible H07V-K and ferrule according to DIN 46 228/1 mm
2
Plug gauge according to 60 947-7-1 Size
Continuous current of terminal for conductor size
Continuous current rating of cross-connection 2…5-pole A
Continuous current rating of cross-connection 6…10-pole A
Rated data according to UL/CSA
Voltage/current/conductor size UL
Voltage/current/conductor size CSA
Ordering data Version
KrG
Blue KrG
KrS
PA
Blue PA
Orange PA
Terminal block with marking PA
Terminal block without marking PA
End plate (thickness mm)
KrG
Blue KrG
KrS
PA
Blue PA
PA
Blue PA
Partition (thickness mm)
TW WTW KrG
Blue KrG
KrS
PA
Blue PA
HP
Small partition
TSch 1
Cross-connection
Q 4 2-pole
3-pole
4-pole
10-pole
Cover plates
Switchable cross-connection link
VL 2 BS VH
Marking tags Print
DEK Standard
SAKD 2.5 N
SAKD 2.5/10/35
SAK 2.5/35
SAK 2.5/10/35
SAK 4/35
SAK 4/10/35
SAK 2.5
SAK 2.5/10
a r # LR
u
5/32.5/43.5
5/44/38
10/M 2.5/3.5 x 0.6
500 V/24 A/2.5 mm
2
6 kV/3
0.4…0.6
1
0.5…4
0.5…2.5
0.5…4
0.5…2.5
A 2
30 A/4 mm
2
24
24
300 V/20 A/28…12 AWG
300 V/20 A/22…12 AWG
Y Qty. W Qty.
021556000010 0 026886000010 0
021558000010 0 0268880000100
0401060000 10 0523160000 10
0401160000 10
Type Cat. No. Qty.
AP (1.5) 0150960000 20
AP (1.5) 0150980000 20
TW (1.5) 0191860000 20
TW (1.5) 0191880000 20
TW (1.5) 0307500000 20
TSch 3 0366860000 100
Q 2 0367800000 50
Q 3 0367900000 50
Q 4 0368000000 50
Q 10 0368100000 20
DEK5 see “Accessories”
a r
i
# LR
u
6/45/40
10/M 2.5/3.5 x 0.6
800 V/24 A/2.5 mm
2
8 kV/3
0.4…0.6
1
0.5…6
0.5…2.5
0.5…4
0.5…2.5/4
3
)
A 3
32 A/4 mm
2
32
600 V/20 A/22…12 AWG
600 V/25 A/26…10 AWG
W Cat. No. Qty.
0380420000 100
0380470000 100
0380460000
1
)100
0380480000
1
)100
0499460000
1
)10
0499560000
1
)10
Type Cat. No. Qty.
AP (1.5) 0279520000 20
AP (1.5) 0279570000 20
AP (1.5) 0279530000 20
AP (1.5) 0460560000 20
AP (1.5) 0460580000 20
TW (2.5) 0302820000 20
TW (2.5) 0302870000 20
TW (2.5) 0302830000 20
TW (1.5) 0302860000 20
TW (1.5) 0302880000 20
TW (1.0) 0297100000 20
TSch 1 0319160000 100
Q 2 0337000000 50
Q 3 0337100000 50
Q 4 0337200000 50
Q 10 0368700000 20
AD 4 0303400000 50
BSKM3x22 0128900000 100
DEK 6 see “Accessories”
a r
i
# LR
u DNV
6/36.5/46.5
10/M 2.5/3.5 x 0.6
800 V/24 A/2.5 mm
2 3)
8 kV/3
0.4…0.6
1
0.5…6
0.5…2.5
0.5…4
0.5…2.5/4
3
)
A 3
32 A/4 mm
2
32
600 V/20 A/22…12 AWG
600 V/25 A/26…10 AWG
Y Cat. No. Qty.
0279620000 100
0279670000 100
0279630000 100
0279660000
1
)
2
)100
0279680000
1
)
2
)100
1326360000
1
)
2
)100
0322560000
1
)
2
)10
0322860000
1
)
2
)10
Type Cat. No. Qty.
AP (1.5) 0279520000 20
AP (1.5) 0279570000 20
AP (1.5) 0279530000 20
AP (1.5) 0279560000 20
AP (1.5) 0279580000 20
TW (2.5) 0302820000 20
TW (2.5) 0302870000 20
TW (2.5) 0302830000 20
TW (1.5) 0302860000 20
TW (1.5) 0302880000 20
TW (1.0) 0297100000 20
TSch 1 0319160000 100
Q 2 0337000000 50
Q 3 0337100000 50
Q 4 0337200000 50
Q 10 0368700000 20
AD 4 0303400000 50
BSKM3x220128900000 100
DEK6 see “Accessories”
a r
i
#
6.5/40/51.5
6.5/45/44
12/M 3/3.5 x 0.6
800 V/32 A/4 mm
2
8 kV/3
0.5…1.0
2
0.5…6
0.5…4
0.5…4
0.5…4
A 4
41 A/6 mm
2
36
600 V/20 A/22…12 AWG
600 V/36 A/26…10 AWG
W Cat. No. Qty.
0443620000 100
0443670000 100
0443660000
1
) 100
0443680000
1
) 100
1323660000
1
) 100
0530460000
1
)10
0530360000
1
)10
Type Cat. No. Qty.
AP (1.5) 0117920000 20
AP (1.5) 0117970000 20
AP (1.5) 0117930000 20
AP (1.5) 0117960000 20
AP (1.5) 0117980000 20
TW (2.5) 0130120000 20
TW (2.5) 0103170000 20
TW (2.5) 0130130000 20
TW (1.5) 0130160000 20
TW (1.5) 0130180000 20
TW (1.0) 0197100000 20
TSch 1 0319160000 100
Q 2 0336700000 50
Q 3 0336800000 50
Q 4 0336900000 50
Q 10 0368800000 20
AD 4 0285300000 50
BSKM3x220128900000 100
VL 2 0197000000 100
VH 0285100000 50
BS 0292500000 100
DEK6.5 see “Accessories”
1234567NEXT