Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

B32520C1104J189

Part # B32520C1104J189
Description CAP FILM 0.1UF 5% 100VDC RADIAL
Additional Information:


Category CAPACITOR
Availability Out of Stock
Qty 0
Qty Price
1 + $0.13200



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

Technical data
Operating temperature range Max. operating temperature T
op,max
+125 °C
Upper category temperature T
max
+125 °C
Lower category temperature T
min
55 °C
Rated temperature T
R
+85 °C
Dissipation factor tan δ (in 10
-3
) at C
R
0.1 µF 0.1 µF < C
R
1 µF C
R
> 1 µF
at 20 °C
1 kHz 8 8 10
(upper limit values) 10 kHz 15 15
100 kHz 30
Insulation resistance R
ins
V
R
C
R
0.33 µF C
R
> 0.33 µF
or time constant τ = C
R
R
ins
100 V DC 3750 M 1250 s
at 20 °C, rel. humidity 65% 250 V DC 7500 M 2500 s
(minimum as-delivered values)
DC test voltage 1.4 V
R
, 2 s
Category voltage V
C
T
A
(°C) DC voltage derating AC voltage derating
(continuous operation with V
DC
T
A
85 V
C
= V
R
V
C,RMS
= V
RMS
or V
AC
at f 60 Hz) 85<T
A
125 V
C
= V
R
(165T
A
)/80 V
C,RMS
=V
RMS
(165T
A
)/80
Operating voltage V
op
for
T
A
(°C) DC voltage (max. hours) AC voltage (max. hours)
short operating periods T
A
100 V
op
= 1.25 V
C
(2000 h) V
op
= 1.0 V
C,RMS
(2000 h)
(V
DC
or V
AC
at f 60 Hz) 100<T
A
125 V
op
= 1.25 V
C
(1000 h) V
op
= 1.0 V
C,RMS
(1000 h)
Damp heat test 56 days/40 °C/93% relative humidity
Limit values after damp Capacitance change C/C 5%
heat test Dissipation factor change tan δ 5 10
-3
(at 1 kHz)
Insulation resistance R
ins
50% of minimum
or time constant τ = C
R
R
ins
as-delivered values
Reliability:
Failure rate λ 1 fit (1 10
-9
/h) at 0.5 V
R
, 40 °C
Service life t
SL
200 000 h at 1.0 V
R
, 85 °C
For conversion to other operating conditions and temperatures,
refer to chapter "Quality, 2 Reliability".
Failure criteria:
Total failure Short circuit or open circuit
Failure due to variation Capacitance change C/C > 10%
of parameters Dissipation factor tan δ > 2 upper limit value
Insulation resistance R
ins
< 150 M(C
R
0.33 µF)
or time constant τ = C
R
R
ins
< 50 s (C
R
> 0.33 µF)
B32520 ... B32529
General purpose (stacked/wound)
Page 22 of 45Please read Important notes
at the end of this document.
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k
0
" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V
2
/µs.
Note:
The values of dV/dt and k
0
provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt values
S = Stacked, W = Wound
Lead spacing 5 mm 7.5 mm 10 mm 15 mm 22.5 mm 27.5 mm 37.5 mm
Technology S S S W S W W W W
V
R
V
RMS
V DC V AC dV/dt in V/µs
63 40 250 120 50 30 3 1 0.8
100 63 300 150 75 50 5 4 3 1
250 160 400 200 150 100 10 8 5 4
400 200 600 275 175 125 10 8.5 6
450 200 20
630 400 800 320 150 15 12
k
0
values
S = Stacked, W = Wound
Lead spacing 5 mm 7.5 mm 10 mm 15 mm 22.5 mm 27.5 mm 37.5 mm
Technology S S S W S W W W W
V
R
V
RMS
V DC V AC k
0
in V
2
/µs
63 40 30000 15000 6300 3800 375 130 100
100 63 60000 30000 15000 10000 850 800 600 200
250 160 200000 100000 75000 50000 5000 4000 2500 2000
400 200 500000 220000 140000 100000 10000 8500 6000
450 200 15000
630 400 1000000 400000 190000 18000 15000
B32520 ... B32529
General purpose (stacked/wound)
Page 23 of 45Please read Important notes
at the end of this document.
Impedance Z versus frequency f
(typical values)
B32520 ... B32529
General purpose (stacked/wound)
Page 24 of 45Please read Important notes
at the end of this document.
PREVIOUS1234567891011121314NEXT